Filters
Variable Frequency Drives (VFD)
part#
description
manufacturer
C200-05500069A10101AB100
NIDEC C200-05500069A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 500Vac-575Vac and has dimensions of frame size 5 H15.39" x W5.63" x D7.87" (H391mm x W143mm x D200mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 10A for Normal duty and 6.9A for Heavy-duty. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation is between -20°C and +60°C. It features 1 analog output (10Vdc; source; single-ended), 5 digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and one 2A / 240Vac; source; relay contact type). Additionally, it includes 2 analog inputs (one 0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution and one 0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 5.5kW for Normal duty and 4kW for Heavy-duty, with a rated power of 7.5HP / 7-1/2HP for Normal duty and 5HP for Heavy-duty.
Nidec
Quick Quote
C200-06200440A10101AB100
NIDEC C200-06200440A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and has dimensions of frame size 6 H15.39" x W8.27" x D8.94" (H291mm x W210mm x D227mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 58A for Normal duty and 44A for Heavy-duty applications. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (1 x 50mA / 0-24Vdc; source; PWM and 1 x 2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). It is rated for an active power of 15kW (Normal duty) and 11kW (Heavy-duty), corresponding to 20HP and 15HP, respectively.
Nidec
Quick Quote
C200-05400300A10101AB100
NIDEC C200-05400300A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and has dimensions of frame size 5 H15.39" x W5.63" x D7.87" (H391mm x W143mm x D200mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 30A for both normal and heavy-duty operations. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 analog output (10Vdc; source; single-ended), 5 digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and one 2A / 240Vac; source; relay contact type). The device also includes 2 analog inputs (one 0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution and one 0-10Vdc; single-ended; 11-bit conversion resolution). It is rated for an active power of 15kW and a power of 20HP for both normal and heavy-duty applications.
Nidec
Quick Quote
C200-05200250A10101AB100
NIDEC C200-05200250A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and has dimensions of frame size 5 H15.39" x W5.63" x D7.87" (H391mm x W143mm x D200mm). This model offers a degree of protection rated at IP20 NEMA 1 and supports a rated current of 30A under normal duty and 25A under heavy-duty conditions. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation is specified from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and another 2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). It is rated for an active power of 7.5kW under normal duty and 5.5kW under heavy-duty, corresponding to 10HP and 7.5HP / 7-1/2HP, respectively.
Nidec
Quick Quote
C200-05400270A10101AB100
NIDEC C200-05400270A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and has dimensions of frame size 5 H15.39" x W5.63" x D7.87" (H391mm x W143mm x D200mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 30A for Normal duty and 27A for Heavy-duty. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) along with 1 x digital output (2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). It is rated for an active power of 15kW (Normal duty) and 11kW (Heavy-duty), with a rated power of 20HP for both Normal and Heavy-duty operations.
Nidec
Quick Quote
C200-05500030A10101AB100
NIDEC C200-05500030A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 500Vac-575Vac and features a frame size of 5, measuring H15.39" x W5.63" x D7.87" (H391mm x W143mm x D200mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 3.9A under normal duty and 3A under heavy-duty conditions. It utilizes the Modbus RTU communication protocol over a 3-phase input network, with a supply input frequency range of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It includes 1 analog output (10Vdc; source; single-ended), 5 digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and one 2A / 240Vac; source; relay contact type). The device also features 2 analog inputs (one 0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution and one 0-10Vdc; single-ended; 11-bit conversion resolution). It has a rated active power of 2.2kW under normal duty and 1.5kW under heavy-duty, corresponding to a rated power of 3HP and 2HP, respectively.
Nidec
Quick Quote
C200-04400170A10101AB100
NIDEC C200-04400170A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and has dimensions of frame size 4 H10.9" x W4.5" x D6.9" (H277mm x W115mm x D175mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 17A for both normal and heavy-duty operations. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power and power in HP are both 7.5kW and 10HP for normal and heavy-duty applications, respectively.
Nidec
Quick Quote
C200-04400135A10101AB100
NIDEC C200-04400135A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and has dimensions of frame size 4 H10.9" x W4.5" x D6.9" (H277mm x W115mm x D175mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 13.5A for both normal and heavy-duty operations. It utilizes Modbus RTU for communication and is compatible with a 3-phase input network, with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and another 2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). It is rated for an active power of 5.5kW and a power of 7.5HP / 7-1/2HP for both normal and heavy-duty applications.
Nidec
Quick Quote
C200-04200176A10101AB100
NIDEC C200-04200176A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and has dimensions of frame size 4 H10.9" x W4.5" x D6.9" (H277mm x W115mm x D175mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 17.6A for both normal and heavy-duty operations. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 digital output (2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). It is rated for an active power of 4kW and a power of 5HP for both normal and heavy-duty applications.
Nidec
Quick Quote
C200-04200133A10101AB100
NIDEC C200-04200133A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and has dimensions of frame size 4 H10.9" x W4.5" x D6.9" (H277mm x W115mm x D175mm), with a degree of protection rated at IP20 NEMA 1. The rated current is 13.3A for both normal and heavy-duty operations. It supports Modbus RTU communication protocol and can be used with either single-phase input (2P) or 3-phase input (3P) networks, with a network frequency of 45-66 Hz (supply input) and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power and power in HP are both 3kW and 3HP for normal and heavy-duty applications.
Nidec
Quick Quote
C200-03400073A10101AB100
NIDEC C200-03400073A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 380Vac-480Vac, including 400Vac and 415Vac, within a frame size 3, measuring H8.9" x W3.54" x D6.3" (H226mm x W90mm x D160mm). This model offers a degree of protection rated at IP20 NEMA 1 and supports a rated current of 7.3A for both normal and heavy-duty operations. It utilizes Modbus RTU for communication and is compatible with a 3-phase input network, with a supply input frequency range of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation spans from -20°C to +60°C. It features 1 analog output (10Vdc; source; single-ended), 5 digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and another 2A / 240Vac; source; relay contact type). Additionally, it includes 2 analog inputs (one 0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution and another 0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power and power in HP for both normal and heavy-duty operations are 3kW and 3HP, respectively.
Nidec
Quick Quote
C200-03400094A10101AB100
NIDEC C200-03400094A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 380Vac-480Vac, including 400Vac and 415Vac, within a frame size 3, measuring H8.9" x W3.54" x D6.3" (H226mm x W90mm x D160mm). This model offers a degree of protection rated at IP20 NEMA 1 and supports a rated current of 9.4A for both normal and heavy-duty applications. It utilizes the Modbus RTU communication protocol over a 3-phase input network, with a supply input frequency range of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation spans from -20°C to +60°C. It features 1 analog output (10Vdc; source; single-ended), 5 digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and another 2A / 240Vac; source; relay contact type). Additionally, it includes 2 analog inputs (one 0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution and another 0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power and power in HP for both normal and heavy-duty operations are 4kW and 5HP, respectively.
Nidec
Quick Quote
C200-03400056A10101AB100
NIDEC C200-03400056A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter within the C200 series, designed with air cooling. It operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and has dimensions of frame size 3 H8.9" x W3.54" x D6.3" (H226mm x W90mm x D160mm), with a degree of protection rated at IP20 NEMA 1. The rated current is 5.6A for both normal and heavy-duty operations. It supports Modbus RTU communication protocol over a 3-phase input network, with a network frequency of 45-66 Hz (supply input) and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 2.2kW and the rated power is 3HP for both normal and heavy-duty applications.
Nidec
Quick Quote
C200-03200100A10101AB100
NIDEC C200-03200100A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and has dimensions of frame size 3 H8.9" x W3.54" x D6.3" (H226mm x W90mm x D160mm), with a degree of protection rated at IP20 NEMA 1. The rated current is 10A for both normal and heavy-duty operations. It supports Modbus RTU communication protocol and can be used with either single-phase input (2P) or 3-phase input (3P) networks, with a network frequency of 45-66 Hz (supply input) and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 2.2kW, and the rated power is 3HP for both normal and heavy-duty applications.
Nidec
Quick Quote
C200-02400032A10101AB100
NIDEC C200-02400032A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and has dimensions of frame size 2 H8.07" x W2.95" x D5.9" (H205mm x W75mm x D150mm), with a degree of protection rated at IP20 NEMA 1. The rated current is 3.2A for both normal and heavy-duty operations. It supports Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). It has a rated active power of 1.1kW and a rated power of 1.5HP / 1-1/2HP for both normal and heavy-duty applications.
Nidec
Quick Quote
C200-02400023A10101AB100
NIDEC C200-02400023A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and has dimensions of frame size 2 H8.07" x W2.95" x D5.9" (H205mm x W75mm x D150mm). This model offers a degree of protection of IP20 NEMA 1 and is rated for a current of 2.3A for both normal and heavy-duty operations. It supports Modbus RTU communication protocol and is designed for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 digital output (2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). It is rated at 0.75kW (1HP) for both normal and heavy-duty applications.
Nidec
Quick Quote
C200-02400018A10101AB100
NIDEC C200-02400018A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and has dimensions of frame size 2 H8.07" x W2.95" x D5.9" (H205mm x W75mm x D150mm). This model offers a degree of protection of IP20 NEMA 1 and is rated for a current of 1.8A for both normal and heavy-duty operations. It supports Modbus RTU communication protocol and is designed for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 digital output (2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). It has a rated active power of 0.55kW and a rated power of 3/4HP for both normal and heavy-duty applications.
Nidec
Quick Quote
C200-02400013A10101AB100
NIDEC C200-02400013A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and has dimensions of frame size 2 H8.07" x W2.95" x D5.9" (H205mm x W75mm x D150mm), with a degree of protection rated at IP20 NEMA 1. The rated current is 1.3A for both normal and heavy-duty operations. It supports Modbus RTU communication protocol over a 3-phase input network, with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 0.37kW and the rated power is 1/2HP for both normal and heavy-duty applications.
Nidec
Quick Quote
C200-02200075A10101AB100
NIDEC C200-02200075A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and is housed within a frame size 2, measuring H8.07" x W2.95" x D5.9" (H205mm x W75mm x D150mm). This model offers a degree of protection rated at IP20 NEMA 1 and supports a rated current of 7.5A for both normal and heavy-duty operations. It utilizes the Modbus RTU communication protocol and can be connected to either a single-phase input (2P) or a 3-phase input (3P) network, with a network frequency range of 45-66 Hz (Supply input) and an output frequency range of 0-550 Hz. The ambient air temperature for operation spans from -20°C to +60°C. For connectivity, it features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 x digital outputs (one 50mA / 0-24Vdc; source; PWM and another 2A / 240Vac; source; relay contact type). It also includes 2 x analog inputs (one 0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution and another 0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 1.5kW and the rated power is 2HP for both normal and heavy-duty applications.
Nidec
Quick Quote
M000-09201760DU0100AB100
NIDEC M000-09201760DU0100AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter, part of the M000 series, designed with a built-in brake transistor and a built-in DC to AC inverter featuring air cooling. It has dimensions of frame size 9D, measuring H28.11" x W12.2" x D11.4" (H714mm x W310mm x D290mm). This model is rated for a heavy-duty current of 176A and operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac), with a network frequency supply input of 50 Hz. It offers a degree of protection of IP20 NEMA 1. The rated active power ranges from 90kW to 250kW for heavy-duty applications, equivalent to 125HP to 400HP.
Nidec
Quick Quote
Items per page: